Articles | Volume 5, issue 1
https://doi.org/10.5194/se-5-1-2014
© Author(s) 2014. This work is distributed under
the Creative Commons Attribution 3.0 License.Assessing accuracy of gas-driven permeability measurements: a comparative study of diverse Hassler-cell and probe permeameter devices
Download
- Final revised paper (published on 02 Jan 2014)
- Preprint (discussion started on 02 Aug 2013)
Interactive discussion
AC: Author comment | RC: Referee comment | SC: Short comment | EC: Editor comment
- Printer-friendly version
- Supplement
-
RC C433: 'se-2013-33 reviewer report', Haakon Fossen, 15 Aug 2013
-
AC C459: 'answer to reviewer H.Fossen', Claudio Filomena, 27 Aug 2013
- SC C468: 'Correction to answer No.2', Claudio Filomena, 28 Aug 2013
-
AC C459: 'answer to reviewer H.Fossen', Claudio Filomena, 27 Aug 2013
-
RC C552: 'Comments', Anonymous Referee #2, 27 Sep 2013
- AC C603: 'Answer to comments of Referee No.2', Claudio Filomena, 16 Oct 2013